AC single-phase nominal voltage, V | 220/230 V |
Network frequency, Hz | 45-65 |
Temperature measurement error, °С | 2 |
Harmonics (non-sinusoidal) of power voltage | EN 50160 |
Temperature control range (it isn't recommended to establish temperature higher than +60°С), °С | from -10 to +90 |
Hysteresis by temperature, °С | 0.1 ...30 |
Actuation threshold control range: – by minimum voltage, V – by maximum voltage, V | 120 - 210 230 - 320 |
Fixed operating time by U mах, seconds | 0.5 |
Fixed off-delay by U min, seconds | 7 |
Fixed operating time when voltage decrease lower than 120 V, seconds | 0.12 |
Fixed operating time when pulse voltage increase more than 450 V while pulse duration more than 1 ms, seconds, not more than | 0.02 |
Actuation threshold determination error by voltage, not more than, V | 3 |
Return hysteresis by voltage, V | 5 |
Minimum voltage, preserving functionality (RMS value), V | 120 |
Maximum switching current when active load, А | 16 |
Maximum voltage, preserving functionality (RMS value), V | 320 |
Output contacts switching resource: – Under the load of 16 А, one time, not less than – Under the load of 5 А, one time, not less than | 100 thous. 1 mio. |
Power consumption when non-connected load, W, not more than | 1.3 |
Connected load power, kW, not more than | 3.6 |
Weight, kg, not more than | 0.16 |
Dimensions, НхВхL, mm | 122 х 61 х 76 |
The device preserves functionality in any position within the space |
Casing material – self-extinguishing plastic |