Solid state relay 77.31.8.230.8050

  • Model: 005.066.143
Solid state relay 77.31.8.230.8050
Manufacturer: Finder (Italy)
Modular solid state relay 77.01.8.230.8050 is applicable for lamp inrush current reduction (CFL - Compact Fluorescent energy-saving Lamps and similar), heater control and soldenoid, contactor driver.
• 1 normally open contact (1NO) for 30A;
• Zero-crossing switch-on;
• 35mm DIN rail mount;
• "Relay-style" terminal arrangement.
$75.96
 pcs

Characteristics

Output specification
Output configuration1 NO (SPST-NO)
Rated current In/ Max peak current (10ms)30А/520А
Rated voltage400V АС
Rated voltage range(60...440)V АС
Switching voltage range(48...480)V АС
Repetitive peak off-state voltage1100V
Rated load АС7а (cos φ= 0.8)30A
Rated load АС1520А
Single phase motor rating (230V АС)
230V lamps ratingincandescent/halogen 6000W
compact fluorescent (CFL)/led 4000W
electronic ballast fluorescent tubes 6000W
electromagnetic ballast compensated fluorescent tubes 3000W
Min switching current at 400V AC300 mA
Typical off-state leakage current at 400V mA1 mA
Max on-state voltage drop at t=25°C and 30А0,85V
Power loss at 30А16W
Input specification
Nominal voltage Un230V AC
Rated powerАС (50 Hz) 7.5VA
DC 0.9W
Operating range(40...280)V AC
Must drop-out voltage, АС6V
Technical data
Electrical life10·106 cycles
Operate/release time<10/<30 ms
Insulation between input and output (1,2/50 μs)6kV
Dielectric strengtd3000V АС
Ambient temperature-20°C...+80°C
Protection categoryIP20
Terminals
Screw torque0,8 N·m
Max solid cable size1x6/2x4 mm2
1x10/2x12 AWG
Max stranded cable size1х6/2х4 mm2
1х10/2х12 AWG
Wire strip lengtd9 mm

Output specification

Output RMS current vs ambient temperature
Output RMS current vs ambient temperature for relay 77.31.8.230.8050
Inrush peak current vs inrush time
Inrush peak current vs time for relay 77.31.8.230.8050

Dimensions and simplified circuit diagram

Dimensions and simplified circuit diagram of relays series 77.31
Questions