Relay RPM42FD

  • Model: 005.006.083
Relay RPM42FD
Manufacturer: Schneider Electric
Barcode: 3389119402255
Electromagnetic plug-in relay, 4 changeover contacts. Control circuit voltage 110Vdc. With LED indicator.

Main

range of productHarmony Electromechanical Relays
series namePower
product or component typePlug-in relay
device short nameRPM
contacts type and composition4 C/O
[Uc] control circuit voltage110 V DC
[Ithe] conventional enclosed thermal current15 A at -40…55 °C
status LEDWith
control typeLockable test button
utilisation coefficient20 %

Complementary

shape of pinFlat
[Ui] rated insulation voltage250 V conforming to IEC
300 V conforming to CSA
300 V conforming to UL
[Uimp] rated impulse withstand voltage4 kV during 1.2/50 µs
contacts materialAgNi
[Ie] rated operational current15 A at 277 V (AC) conforming to UL
15 A at 28 V (DC) conforming to UL
15 A at 250 V (AC) NO conforming to IEC
15 A at 28 V (DC) NO conforming to IEC
7.5 A at 250 V (AC) NC conforming to IEC
7.5 A at 28 V (DC) NC conforming to IEC
maximum switching voltage250 V conforming to IEC
Resistive load current15 A at 250 V AC
15 A at 28 V DC
maximum switching capacity3750 VA
420 W
minimum switching capacity170 mW at 10 mA, 17 V
operating rate≤ 1200 cycles/hour under load
≤ 18000 cycles/hour no-load
mechanical durability10000000 cycles
electrical durability100000 cycles for resistive load
Average coil consumption1.6 W
drop-out voltage threshold>= 0.1 Uc DC
Operate time20 ms at nominal voltage
Release time20 ms at nominal voltage
Average coil resistance6370 Ohm at 20 °C +/- 10 %
rated operational voltage limits88...121 V DC
protection categoryRT I
test levelsLevel A group mounting
operating positionAny position
pollution degree3
safety reliability dataB10d = 100000
net weight0.071 kg
device presentationComplete product

Environment

dielectric strength1500 V AC between contacts with micro disconnection
2000 V AC between coil and contact with reinforced
2000 V AC between poles with basic
standardsUL 508
EN/IEC 61810-1
CSA C22.2 No 14
product certificationsUL
CSA
EAC
ambient air temperature for storage-40…85 °C
ambient air temperature for operation-40…55 °C
vibration resistance3 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles in operation
5 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles not operating
Degree of protection (Housing only)IP40 conforming to EN/IEC 60529
shock resistance15 gn for in operation
30 gn for not operating

Auxiliaries and accessories for RPM42FD

background
RPZF4
 
 
Questions
WhatsAppTelegramViberVKemail