Relay G7L-TU-2A 220VAC

  • Model: 005.081.015
Relay G7L-TU-2A 220VAC
Designed for high inrush current load. Aplication air-condition refrigeratory, compressot etc.
Analogue of the relay JQX-76F-TU-2A.

Technical Data

ParametersContact form 2A
Rated loadresistive: 277VAC, 25A
motor: 1.5HP/120VAC, 3HP/240VAC
Operating power (resistive)6925VA
Contact resistance (initial)≤50mΩ
contacts materialAg alloy
Lifeelectrical: ≥105 cycles (1800 Ops/h)
mechanical: ≥106 cycles (1800 Ops/h)
Operate voltage (at 25°C)AC,DC: ≤75% rated voltage
Release voltage (at 25°C)AC,DC: ≥15% rated voltage
Max allowed voltage(at 25°C)110% rated voltage
Insulation resistance≥100MΩ (500VDC)
Coil power consumption≤2,5 VA
Operate time≤30ms
Release time≤30ms
Dielectric strengthbetween contacts: 2000VAC/1min (leakage current 1 mA)
between contacts (different pole): 2000VAC/1min (leakage current 1 mA)
between contact and coil: 4000VAC/1min (leakage current 1 mA)
Ambient temperature-25°C ÷ +55°C
Weight90g
Kit electric outletP76F-06

Coil type (25°C)

Rated voltage, VDC6122448100110
Coil resistance, Ω (+10%)18,975303122052606360
Rated voltage, VAC122448100-120200-240
Coil resistance, Ω (+10%)652751100473021000

Dimensions

G7L-2P-TUBJ-CB relay drawing

Electrical scheme

power relay G7L02P-TUBJ-CB

Similar or replacement products G7L-TU-2A-220VAC

background
JQX-76F/2Z-220VAC
 
 
Questions
WhatsAppTelegramViberVKemail