Contactor LC1F630MD 3P 630A

  • Model: 004.007.106
Contactor LC1F630MD 3P 630A
Manufacturer: Schneider Electric
Barcode: 3389118094680
The F-line contactors offer proven performance for resistive loads or large motor starting applications such as fans, crushers, pumps, compressors and overhead cranes. They offer high reliability with long mechanical and electrical life and the most complete line of accessories in the industry.
Main
rangeTeSys
product nameTeSys F
product or component typeContactor
device short nameLC1F
contactor applicationMotor control
Resistive load
utilisation categoryAC-4
AC-3
AC-1
poles description3P
power pole contact composition3 NO
[Ue] rated operational voltage≤ 1000 V AC 50/60 Hz
≤ 460 V DC
[Ie] rated operational current1000 A (at < 40 °C) at ≤ 440 V AC AC-1
630 A (at < 55 °C) at ≤ 440 V AC AC-3
motor power kW335 kW at 380...400 V AC 50/60 Hz (AC-3)
375 kW at 415 V AC 50/60 Hz (AC-3)
400 kW at 440 V AC 50/60 Hz (AC-3)
400 kW at 500 V AC 50/60 Hz (AC-3)
450 kW at 660...690 V AC 50/60 Hz (AC-3)
450 kW at 1000 V AC 50/60 Hz (AC-3)
200 kW at 220...230 V AC 50/60 Hz (AC-3)
100 kW at 400 V AC 50/60 Hz (AC-4)
[Uc] control circuit voltage220 V DC
coil typeStandard
Complementary
[Uimp] rated impulse withstand voltage8 kV
overvoltage categoryIII
[Ith] conventional free air thermal current1000 A (at 40 °C)
1250 A
rated breaking capacity5040 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current5050 A 40 °C - 10 s
4400 A 40 °C - 30 s
3400 A 40 °C - 1 min
2200 A 40 °C - 3 min
1600 A 40 °C - 10 min
associated fuse rating1000 A gG at ≤ 440 V
630 A aM at ≤ 440 V
average impedance0.12 mOhm - Ith 1000 A 50 Hz
[Ui] rated insulation voltage1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
power dissipation per pole120 W AC-1
48 W AC-3
mounting supportPlate
standardsIEC 60947-1
JIS C8201-4-1
EN 60947-1
EN 60947-4-1
IEC 60947-4-1
product certificationsRINA
CSA
CB
LROS (Lloyds register of shipping)
RMRoS
DNV
BV
UL
ABS
connections - terminalsControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: bar 2 cable(s) - busbar cross section: 60 x 5 mm
Power circuit: bolted connection
tightening torqueControl circuit: 1.2 N.m
Power circuit: 58 N.m
control circuit voltage limitsOperational: 0.85...1.1 Uc (at 55 °C)
Drop-out: 0.2...0.35 Uc (at 55 °C)
inrush power in W1600 W (at 20 °C)
hold-in power consumption in W9 W at 20 °C
heat dissipation9 W
operating time60...70 ms closing
40...50 ms opening
mechanical durability5 Mcycles
maximum operating rate1200 cyc/h 55 °C
compatibility codeLC1F
motor power range250…500 kW at 380…440 V 3 phases
110…220 kW at 200…240 V 3 phases
250…500 kW at 480…500 V 3 phases
motor starter typeDirect on-line contactor
contactor coil voltage220 V DC standard
Environment
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
protective treatmentTH
ambient air temperature for operation-5…55 °C
ambient air temperature for storage-60…80 °C
permissible ambient air temperature around the device-40…70 °C
height304 mm
width309 mm
depth255 mm
net weight18.6 kg
Questions