Contactor LC1F4004M7

  • Model: 004.008.022
Contactor LC1F4004M7
Manufacturer: Schneider Electric
Barcode: 3389110227017
The F-line contactors offer proven performance for resistive loads or large motor starting applications such as fans, crushers, pumps, compressors and overhead cranes. They offer high reliability with long mechanical and electrical life and the most complete line of accessories in the industry.
Main
rangeTeSys
product nameTeSys F
product or component typeContactor
device short nameLC1F
contactor applicationResistive load
utilisation categoryAC-1
poles description4P
power pole contact composition4 NO
[Ie] rated operational current500 A (at <40 °c) at <=440 v ac ac-1< td>
[Uc] control circuit voltage220 V AC 40...400 Hz
Complementary
[Uimp] rated impulse withstand voltage8 kV
overvoltage categoryIII
[Ith] conventional free air thermal current500 A (at 40 °C)
rated breaking capacity3200 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current3600 A 40 °C - 10 s
2400 A 40 °C - 30 s
1700 A 40 °C - 1 min
1200 A 40 °C - 3 min
1000 A 40 °C - 10 min
associated fuse rating400 A aM at <= 440 V
500 A gG at <= 440 V
average impedance0.26 mOhm - Ith 500 A 50 Hz
[Ui] rated insulation voltage1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
power dissipation per pole65 W AC-1
mounting supportPlate
standardsJIS C8201-4-1
IEC 60947-4-1
IEC 60947-1
EN 60947-4-1
EN 60947-1
product certificationsRMRoS
BV
DNV
RINA
CCC
ABS
CB
UL
LROS (Lloyds register of shipping)
UKCA
connections - terminalsControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: bar 2 cable(s) - busbar cross section: 30 x 5 mm
Power circuit: lugs-ring terminals 2 cable(s) 150 mm²
Power circuit: bolted connection
tightening torqueControl circuit: 1.2 N.m
Power circuit: 35 N.m
control circuit voltage limitsOperational: 0.85...1.1 Uc 40...400 Hz (at 55 °C)
Drop-out: 0.3...0.5 Uc 40...400 Hz (at 55 °C)
inrush power in VA1075 VA 40...400 Hz cos phi 0.9 (at 20 °C)
hold-in power consumption in VA15 VA 40...400 Hz cos phi 0.9 (at 20 °C)
heat dissipation14 W
operating time40...65 ms closing
100...170 ms opening
mechanical durability10 Mcycles
maximum operating rate2400 cyc/h 55 °C
compatibility codeLC1F
Environment
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
protective treatmentTH
ambient air temperature for operation-5…55 °C
ambient air temperature for storage-60…80 °C
permissible ambient air temperature around the device-40…70 °C
operating altitude3000 m without derating
height206 mm
width261 mm
depth219 mm
net weight10.2 kg
Questions
WhatsAppTelegramViberVKemail