Contactor LC1F185M5 3P 185A

  • Model: 004.007.115
Contactor LC1F185M5 3P 185A
Manufacturer: Schneider Electric
Barcode: 3389110122411
The F-line contactors offer proven performance for resistive loads or large motor starting applications such as fans, crushers, pumps, compressors and overhead cranes. They offer high reliability with long mechanical and electrical life and the most complete line of accessories in the industry.
Main
rangeTeSys
product nameTeSys F
product or component typeContactor
device short nameLC1F
contactor applicationMotor control
Resistive load
utilisation categoryAC-1
AC-3
AC-4
poles description3P
power pole contact composition3 NO
[Ue] rated operational voltage≤ 460 V DC
≤ 690 V AC 50/60 Hz
[Ie] rated operational current275 A (at < 40 °C) at ≤ 440 V AC-1
185 A (at < 55 °C) at ≤ 440 V AC-3
motor power kW90 kW at 380...400 V AC 50/60 Hz (AC-3)
100 kW at 415 V AC 50/60 Hz (AC-3)
100 kW at 440 V AC 50/60 Hz (AC-3)
110 kW at 500 V AC 50/60 Hz (AC-3)
110 kW at 660...690 V AC 50/60 Hz (AC-3)
55 kW at 220...230 V AC 50/60 Hz (AC-3)
33 kW at 400 V AC 50/60 Hz (AC-4)
[Uc] control circuit voltage220 V AC 50 Hz
Complementary
[Uimp] rated impulse withstand voltage8 kV
overvoltage categoryIII
[Ith] conventional free air thermal current275 A (at 40 °C)
rated breaking capacity1480 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current1500 A 40 °C - 10 s
920 A 40 °C - 30 s
740 A 40 °C - 1 min
500 A 40 °C - 3 min
400 A 40 °C - 10 min
associated fuse rating200 A aM at ≤ 440 V
315 A gG at ≤ 440 V
average impedance0.33 mOhm - Ith 275 A 50 Hz
[Ui] rated insulation voltage1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
power dissipation per pole12 W AC-3
25 W AC-1
mounting supportPlate
standardsEN 60947-1
EN 60947-4-1
IEC 60947-1
JIS C8201-4-1
IEC 60947-4-1
product certificationsABS
RINA
BV
RMRoS
UL
LROS (Lloyds register of shipping)
CCC
CB
DNV
connections - terminalsControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: bar 2 cable(s) - busbar cross section: 25 x 3 mm
Power circuit: lugs-ring terminals 1 cable(s) 150 mm²
Power circuit: connector 1 cable(s) 150 mm²
Power circuit: bolted connection
tightening torqueControl circuit: 1.2 N.m
Power circuit: 18 N.m
control circuit voltage limitsOperational: 0.85...1.1 Uc 50/60 Hz (at 55 °C)
Drop-out: 0.35...0.55 Uc 50/60 Hz (at 55 °C)
inrush power in VA805 VA 50 Hz cos phi 0.3 (at 20 °C)
hold-in power consumption in VA55 VA 50 Hz cos phi 0.3 (at 20 °C)
heat dissipation18…24 W
operating time20...35 ms closing
7...15 ms opening
mechanical durability10 Mcycles
maximum operating rate2400 cyc/h 55 °C
compatibility codeLC1F
Environment
IP degree of protectionIP2x front face with shrouds conforming to IEC 60529
IP2x front face with shrouds conforming to VDE 0106
protective treatmentTH
ambient air temperature for operation-5…55 °C
ambient air temperature for storage-60…80 °C
permissible ambient air temperature around the device-40…70 °C
operating altitude3000 m without derating
height174 mm
width168.5 mm
depth181 mm
net weight4.65 kg

Similar or replacement products LC1F185M5

background
LC1F185M7
 
 
background
LC1F185P7
 
 
background
SQ0710-0005
 
 
Questions
WhatsAppTelegramViberVKemail