Contactor LC1F1854M7

  • Model: 004.008.018
Contactor LC1F1854M7
Manufacturer: Schneider Electric
Barcode: 3389110788129
The F-line contactors offer proven performance for resistive loads or large motor starting applications such as fans, crushers, pumps, compressors and overhead cranes. They offer high reliability with long mechanical and electrical life and the most complete line of accessories in the industry.
Main
rangeTeSys
product nameTeSys F
product or component typeContactor
device short nameLC1F
contactor applicationResistive load
utilisation categoryAC-1
poles description4P
power pole contact composition4 NO
[Ue] rated operational voltage≤ 460 V DC
≤ 690 V AC 50/60 Hz
[Ie] rated operational current275 A (at < 40 °C) at ≤ 440 V AC-1
[Uc] control circuit voltage220 V AC 40...400 Hz
Complementary
[Uimp] rated impulse withstand voltage8 kV
overvoltage categoryIII
[Ith] conventional free air thermal current275 A (at 40 °C)
rated breaking capacity1480 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current1500 A 40 °C - 10 s
920 A 40 °C - 30 s
740 A 40 °C - 1 min
500 A 40 °C - 3 min
400 A 40 °C - 10 min
associated fuse rating200 A aM at ≤ 440 V
315 A gG at ≤ 440 V
average impedance0.33 mOhm - Ith 275 A 50 Hz
[Ui] rated insulation voltage1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
power dissipation per pole12 W AC-3
25 W AC-1
mounting supportPlate
standardsEN 60947-1
IEC 60947-1
JIS C8201-4-1
IEC 60947-4-1
EN 60947-4-1
product certificationsRMRoS
CCC
CB
UL
LROS (Lloyds register of shipping)
RINA
ABS
BV
DNV
connections - terminalsControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: bar 2 cable(s) - busbar cross section: 25 x 3 mm
Power circuit: lugs-ring terminals 1 cable(s) 150 mm²
Power circuit: connector 1 cable(s) 150 mm²
Power circuit: bolted connection
tightening torqueControl circuit: 1.2 N.m
Power circuit: 18 N.m
control circuit voltage limitsOperational: 0.85...1.1 Uc 40...400 Hz (at 55 °C)
Drop-out: 0.35...0.55 Uc 40...400 Hz (at 55 °C)
inrush power in VA1070 VA 40...400 Hz cos phi 0.9 (at 20 °C)
hold-in power consumption in VA9.9 VA 40...400 Hz cos phi 0.9 (at 20 °C)
heat dissipation8…9.8 W
operating time35 ms closing (at Uc)
130 ms opening (at Uc)
mechanical durability10 Mcycles
maximum operating rate2400 cyc/h 55 °C
compatibility codeLC1F
Environment
IP degree of protectionIP2x front face with shrouds conforming to IEC 60529
IP2x front face with shrouds conforming to VDE 0106
protective treatmentTH
ambient air temperature for operation-5…55 °C
ambient air temperature for storage-60…80 °C
permissible ambient air temperature around the device-40…70 °C
height174 mm
width208.5 mm
depth181 mm
net weight5.45 kg

Dimensions

Overall sizes of contactor LC1F1854M7       Circuit of contactor LC1F1854M7