Contactor LC1F185

  • Model: 004.007.003
Contactor LC1F185
Manufacturer: Schneider Electric
Barcode: 3389110122381
The F-line contactors offer proven performance for resistive loads or large motor starting applications such as fans, crushers, pumps, compressors and overhead cranes. They offer high reliability with long mechanical and electrical life and the most complete line of accessories in the industry.
Price by call

Main

rangeTeSys
product nameTeSys F
product or component typeContactor
device short nameLC1F
contactor applicationResistive load
Motor control
utilisation categoryAC-3
AC-4
AC-1
poles description3P
power pole contact composition3 NO
[Ue] rated operational voltage≤ 690 V AC 50/60 Hz
[Ie] rated operational current275 A (at < 40 °C) at ≤ 440 V AC-1
185 A (at < 55 °C) at ≤ 440 V AC-3
motor power kW100 kW at 415 V AC 50/60 Hz (AC-3)
100 kW at 440 V AC 50/60 Hz (AC-3)
110 kW at 500 V AC 50/60 Hz (AC-3)
90 kW at 380...400 V AC 50/60 Hz (AC-3)
55 kW at 220...240 V AC 50/60 Hz (AC-3)
110 kW at 660...690 V AC 50/60 Hz (AC-3)
33 kW at 400 V AC 50/60 Hz (AC-4)

Complementary

[Uc] control circuit voltage24...575 V AC 40...400 Hz with LX9 coil
24...460 V DC with LX4 coil
100...250 V AC 50/60 Hz with LXE coil
100...380 V DC with LXE coil
[Uimp] rated impulse withstand voltage8 kV
overvoltage categoryIII
[Ith] conventional free air thermal current275 A (at 40 °C)
Irms rated making capacity1850 A conforming to IEC 60947-4-1
rated breaking capacity1480 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current1500 A 40 °C - 10 s
920 A 40 °C - 30 s
740 A 40 °C - 1 min
500 A 40 °C - 3 min
400 A 40 °C - 10 min
associated fuse rating200 A aM at ≤ 440 V
315 A gG at ≤ 440 V
average impedance0.33 mOhm - Ith 275 A 50 Hz
[Ui] rated insulation voltage1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
power dissipation per pole25 W AC-1
12 W AC-3
control circuit voltage limitsOperational: 0.85...1.1 Uc AC 40...400 Hz with LX9 coil
Drop-out: 0.2...0.55 Uc AC 40...400 Hz with LX9 coil
Operational: 0.85...1.1 Uc DC with LX4 coil
Drop-out: 0.15...0.2 Uc DC with LX4 coil
Operational: 85...275 V AC 50/60 Hz with LXE coil
Drop-out: 0...60 V AC 50/60 Hz with LXE coil
Operational: 85...418 V DC with LXE coil
Drop-out: 0...45 V DC with LXE coil
heat dissipation8…9.8 W
2.2…2.5 W
operating time35 ms closing for with LX9 coil
130 ms opening for with LX9 coil
30...40 ms closing for with LX4 coil
30...50 ms opening for with LX4 coil
40...80 ms closing for with LXE coil
6...54 ms opening for with LXE coil
mounting supportPlate
standardsIEC 60947-4-1
EN 60947-1
JIS C8201-4-1
EN 60947-4-1
IEC 60947-1
product certificationsABS
LROS (Lloyds register of shipping)
RINA
CSA
CB
UL
BV
RMRoS
DNV
connections - terminalsPower circuit: bar 2 cable(s) - busbar cross section: 25 x 3 mm
Power circuit: lugs-ring terminals 1 cable(s) 150 mm²
Power circuit: connector 1 cable(s) 150 mm²
Power circuit: bolted connection
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²flexible without cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.25…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1.0 cable(s) 0.2…2.5 mm²solid without cable end
tightening torquePower circuit: 18 N.m
Control circuit: 1.2 N.m
Control circuit: 0.6 N.m
mechanical durability10 Mcycles
inrush power in VA950…1180 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil
737…902 VA (at 20 °C)with LX4 coil
280…310 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
270…320 VA (at 20 °C)with LXE coil
hold-in power consumption in VA8.9…10.9 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil
4.13…5.07 VA (at 20 °C)with LX4 coil
4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil
2.5…4.0 VA (at 20 °C)with LXE coil
compatibility codeLC1F

Environment

IP degree of protectionIP2x front face with shrouds conforming to IEC 60529
IP2x front face with shrouds conforming to VDE 0106
protective treatmentTH
ambient air temperature for operation-5…55 °C
ambient air temperature for storage-60…80 °C
permissible ambient air temperature around the device-40…70 °C
mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz
Vibrations contactor closed: 5 Gn, 5...300 Hz
Shocks contactor open: 7 Gn for 1/2 sine wave (11 ms)
Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)
height174 mm
width168.5 mm
depth181 mm
net weight5.45 kg
colour-

Dimensions

Dimension LC1F185
Questions