Contactor LC1BL33M22

  • Model: 004.013.016
Contactor LC1BL33M22
Manufacturer: Schneider Electric
Barcode: 3389110103014
The B-line contactors offer proven performance for resistive loads or large motor starting applications such as fans, crushers, pumps, compressors and overhead cranes. They offer high reliability with long mechanical and electrical life and the most complete line of accessories in the industry.

Main

rangeTeSys
product nameTeSys B
product or component typeContactor
device short nameLC1BL
contactor applicationMotor-heating-lighting
utilisation categoryAC-1
AC-3
AC-4
control circuit typeAC
coil typeStandard
poles description3P
pole contact composition3 NO
[Ie] rated operational current800 A (at < 40 °C) AC AC-1 for power circuit
750 A (at < 55 °C) AC AC-3 for power circuit
motor power kW220 kW at 220...230 V AC 50/60 Hz (AC-3)
400 kW at 380...400 V AC 50/60 Hz (AC-3)
425 kW at 415 V AC 50/60 Hz (AC-3)
450 kW at 440 V AC 50/60 Hz (AC-3)
500 kW at 500 V AC 50/60 Hz (AC-3)
530 kW at 1000 V AC 50/60 Hz (AC-3)
560 kW at 660...690 V AC 50/60 Hz (AC-3)
160 kW at 400 V AC 50/60 Hz (AC-4)
auxiliary contact composition2 NO + 2 NC
[Uc] control circuit voltage220 V AC 50...400 Hz

Complementary

control circuit voltage limitsDrop-out: 0.3...0.5 Uc at 50...400 Hz
Operational: 0.85...1.1 Uc at 50...400 Hz
[Ui] rated insulation voltage1000 V - for power circuit conforming to IEC 60158-1
1000 V - for power circuit conforming to IEC 60947-4
1500 V - for power circuit conforming to VDE 0110 group C
mounting modeFixed
mounting supportNotched mounting rails
Bar support bracket
tightening torquePower circuit: 21 N.m - on bars
[Ue] rated operational voltagePower circuit: ≤ 1000 V AC 50/60 Hz
[Ith] conventional free air thermal current800 A (at 40 °C) for power circuit
Irms rated making capacity10000 A at 1000 V AC for power circuit conforming to IEC 60158-1
10000 A at 1000 V AC for power circuit conforming to IEC 60947-4
rated breaking capacity10000 A at 440 V for power circuit conforming to IEC 60158-1
10000 A at 440 V for power circuit conforming to IEC 60947-4
4000 A at 1000 V for power circuit conforming to IEC 60158-1
4000 A at 1000 V for power circuit conforming to IEC 60947-4
8000 A at 660...690 V for power circuit conforming to IEC 60158-1
8000 A at 660...690 V for power circuit conforming to IEC 60947-4
9000 A at 500 V for power circuit conforming to IEC 60158-1
9000 A at 500 V for power circuit conforming to IEC 60947-4
associated fuse rating1000 A gI at ≤ 440 V for power circuit
800 A aM at ≤ 440 V for power circuit
800 A gI at ≤ 440 V for power circuit
average impedance0.18 mOhm - Ith 800 A 50 Hz for power circuit
power dissipation per pole115 W AC-1 - Ith 800 A
88 W AC-3 - Ith 800 A
inrush power in VA1300 VA
hold-in power consumption in VA31 VA 50/60 Hz
operating time100...150 ms closing
50...100 ms opening
mechanical durability1200000 cycles
maximum operating rate120 cyc/h 55 °C
height486 mm
width570 mm
depth475 mm
net weight58 kg

Environment

standardsNF C 63-110
IEC 60158-1
VDE 0660
IEC 60947-4
BS 5424
product certificationsRINA
CSA
BV
protective treatmentTC
TH
ambient air temperature for operation-5…55 °C
ambient air temperature for storage-60…80 °C
operating altitude3000 m without derating
Questions