Contactor LC1E400F7

  • Model: 004.005.334
  • photo 3
  • photo 4
Contactor LC1E400F7
Manufacturer: Schneider Electric
The contactor LC1E400F7 3P 400A 110V 50/60Hz is used to control:
- three-phase motors up to 110 kW at 220...230 V AC 50/60 Hz.
- Resistive circuits up to 500 A (≤ 40 °C) AC AC-1 for power circuit ≤ 440 V.
Control circuit voltage - 110 V AC 50/60 Hz

Main

rangeEasyPact
product nameEasyPact TVS
product or component typeContactor
device short nameLC1E
contactor applicationResistive load
Motor control
utilisation categoryAC-1
AC-3
poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit: ≤ 690 V AC 50/60 Hz
[Ie] rated operational current400 A (at < 55 °C) at ≤ 440 V AC AC-3 for power circuit
500 A (at < 40 °C) at ≤ 440 V AC AC-1 for power circuit
motor power kW110 kW at 220...230 V AC 50/60 Hz
200 kW at 380...400 V
220 kW at 415 V
250 kW at 440 V
257 kW at 500 V
280 kW at 660...690 V
control circuit typeAC at 50/60 Hz
[Uc] control circuit voltage110 V AC 50/60 Hz
height375 mm
width213 mm
depth219 mm
net weight9.1 kg

Complementary

[Uimp] rated impulse withstand voltage8 kV coil not connected to the power circuit conforming to IEC 60947
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
overvoltage categoryIII
[Ith] conventional free air thermal current500 A (at 40 °C) for power circuit
Irms rated making capacity4000 A at 440 V AC for power circuit conforming to IEC 60947-4-1
rated breaking capacity3200 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current3600 A 40 °C - 10 s for power circuit
associated fuse rating10 A gG at ≤ 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1
630 A gG at ≤ 690 V coordination type 1 for power circuit
average impedance0.26 mOhm - Ith 500 A 50 Hz for power circuit
power dissipation per pole42 W AC-3
65 W AC-1
control circuit voltage limitsOperational: 0.85...1.1 Uc at 50/60 Hz (at < 55 °C)
Drop-out: 0.35...0.5 Uc at 50/60 Hz (at < 55 °C)
operating time100...170 ms on opening
40...75 ms on closing
mechanical durability4000000 cycles
maximum operating rate2400 cyc/h 55 °C
inrush power in VA1075 VA 50 Hz cos phi 0.9 (at 20 °C)
1075 VA 60 Hz cos phi 0.9 (at 20 °C)
hold-in power consumption in VA15 VA 50 Hz cos phi 0.9 (at 20 °C)
15 VA 60 Hz cos phi 0.9 (at 20 °C)
heat dissipation14 W for control circuit
minimum switching current5 mA for control circuit
minimum switching voltage17 V for control circuit
non-overlap time1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
insulation resistance> 10 MOhm for control circuit
electrical durability250000 cycles AC-1
600000 cycles AC-3
mounting supportPlate
connections - terminalsControl circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Power circuit: cable with lug 2 - external diameter: 150 mm
Power circuit: bars 2 - busbar cross section: 30 x 5 mm
Recommended tightening torqueControl circuit: 1.2 N.m
Power circuit: 35 N.m
Max tightening torqueControl circuit: 1.4 N.m
Power circuit: 37 N.m

Environment

standardsIEC 60947-5-1
IEC 60947-4-1
IEC 60947-1
product certificationsEAC
IP degree of protectionIP2x conforming to IEC 60529
protective treatmentTH (pollution degree 3) conforming to IEC 60068
pollution degree3
ambient air temperature for operation-5…55 °C
ambient air temperature for storage-60…80 °C
permissible ambient air temperature around the device-20…70 °C at Uc
operating altitude3000 m without derating
fire resistance850 °C conforming to IEC 60695-2-1
mechanical robustnessVibrations contactor open: 1.5 Gn, 5...300 Hz
Shocks contactor open: 6 Gn for 11 ms
Vibrations contactor closed: 5 Gn, 5...300 Hz
Shocks contactor closed: 15 Gn for 11 ms