Electromechanical contactor LC1E80F5 80A 400V AC3 110V 50Hz used for power management and protection:
 - loads on AC power with a coefficient ≥0.95 (incandescent lamps, heating elements, etc.) - the category of use AC-1. Rated current - 110 Amps.
 - asynchronous squirrel-cage motors - the category of use AC-3. Rated Current - 80 Amps.
Voltage control coil - 110V~ 50Hz.

Main

range EasyPact
product name EasyPact TVS
product or component type Contactor
device short name LC1E
contactor application Resistive load
Motor control
utilisation category AC-3
AC-1
poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit: ≤ 690 V AC 50/60 Hz
[Ie] rated operational current 80 A (at < 60 °C) at ≤ 440 V AC AC-3 for power circuit
110 A (at < 60 °C) at ≤ 440 V AC AC-1 for power circuit
motor power kW 22 kW at 220...230 V AC 50/60 Hz (AC-3)
37 kW at 380...400 V AC 50/60 Hz (AC-3)
45 kW at 415 V AC 50/60 Hz (AC-3)
45 kW at 440 V AC 50/60 Hz (AC-3)
45 kW at 500 V AC 50/60 Hz (AC-3)
45 kW at 660...690 V AC 50/60 Hz (AC-3)
control circuit type AC at 50 Hz
[Uc] control circuit voltage 110 V AC 50 Hz
height 127 mm
width 85 mm
depth 121 mm
net weight 1.52 kg
colour Grey (RAL 7011)

Complementary

auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand voltage 6 kV coil not connected to the power circuit conforming to IEC 60947
[Ui] rated insulation voltage 690 V conforming to IEC 60947-4-1
overvoltage category III
Irms rated making capacity 800 A at 440 V AC for power circuit conforming to IEC 60947-4-1
rated breaking capacity 640 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 640 A 40 °C - 10 s for power circuit
320 A 40 °C - 60 s for power circuit
135 A 40 °C - 600 s for power circuit
associated fuse rating 10 A gG at ≤ 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1
160 A gG at ≤ 690 V coordination type 1 for power circuit
average impedance 0.8 mOhm - Ith 110 A 50 Hz for power circuit
power dissipation per pole 5.1 W AC-3
9.7 W AC-1
control circuit voltage limits Operational: 0.85...1.1 Uc at 50 Hz (at < 55 °C)
Drop-out: 0.3...0.6 Uc at 50 Hz (at < 55 °C)
operating time 20...35 ms on closing
6...30 ms on opening
mechanical durability 300000 cycles
maximum operating rate 1200 cyc/h 60 °C
inrush power in VA 200 VA 50 Hz cos phi 0.75 (at 20 °C)
220 VA 60 Hz cos phi 0.75 (at 20 °C)
hold-in power consumption in VA 22 VA 60 Hz cos phi 0.3 (at 20 °C)
20 VA 50 Hz cos phi 0.3 (at 20 °C)
heat dissipation 6…10 W for control circuit
minimum switching current 5 mA for control circuit
minimum switching voltage 17 V for control circuit
non-overlap time 1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
insulation resistance > 10 MOhm for control circuit
electrical durability 350000 cycles AC-1
900000 cycles AC-3
mounting support Plate
DIN rail
connections - terminals Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 4…16 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 4…50 mm² - cable stiffness: solid without cable end
tightening torque Control circuit: 1.2 N.m
Power circuit: 12 N.m

Environment

standards IEC 60947-1
IEC 60947-4-1
IEC 60947-5-1
product certifications EAC
IP degree of protection IP2x conforming to IEC 60529
protective treatment TH (pollution degree 3) conforming to IEC 60068
pollution degree 3
ambient air temperature for operation -5…55 °C
ambient air temperature for storage -60…80 °C
permissible ambient air temperature around the device -20…70 °C at Uc
operating altitude 3000 m without derating
fire resistance 850 °C conforming to IEC 60695-2-1
mechanical robustness Vibrations contactor open: 1.5 Gn, 5...300 Hz
Vibrations contactor closed: 3 Gn, 5...300 Hz
Shocks contactor open: 6 Gn for 11 ms
Shocks contactor closed: 7 Gn for 11 ms