Contactor LC1E65M5

  • Model: 004.005.080
Contactor LC1E65M5
Manufacturer: Schneider Electric
Barcode: 3606480339165
The E-line contactor LC1E65M5 1NO + 1NC 65A 400V AC3 220V/50Hz offer proven performance for resistive loads or large motor starting applications such as fans, crushers, pumps, compressors and overhead cranes. They offer high reliability with long mechanical and electrical life and the most complete line of accessories in the industry.

Main

range EasyPact
product name EasyPact TVS
product or component type Contactor
device short name LC1E
contactor application Motor control
Resistive load
utilisation category AC-1
AC-3
poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit: ≤ 690 V AC 50/60 Hz
[Ie] rated operational current 65 A (at < 60 °C) at ≤ 440 V AC AC-3 for power circuit
80 A (at < 60 °C) at ≤ 440 V AC AC-1 for power circuit
motor power kW 18.5 kW at 220...230 V AC 50/60 Hz
30 kW at 380...400 V
37 kW at 415 V
37 kW at 440 V
37 kW at 500 V
37 kW at 660...690 V
control circuit type AC at 50 Hz
[Uc] control circuit voltage 220 V AC 50 Hz
height 127 mm
width 75 mm
depth 114 mm
net weight 0.98 kg
colour Grey (RAL 7011)

Complementary

auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand voltage 6 kV coil not connected to the power circuit conforming to IEC 60947
[Ui] rated insulation voltage 690 V conforming to IEC 60947-4-1
overvoltage category III
Irms rated making capacity 650 A at 440 V AC for power circuit conforming to IEC 60947-4-1
rated breaking capacity 520 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 520 A 40 °C - 10 s for power circuit
260 A 40 °C - 60 s for power circuit
110 A 40 °C - 600 s for power circuit
associated fuse rating 10 A gG at ≤ 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1
125 A gG at ≤ 690 V coordination type 1 for power circuit
average impedance 1 mOhm - Ith 80 A 50 Hz for power circuit
power dissipation per pole 4.2 W AC-3
6.4 W AC-1
control circuit voltage limits Operational: 0.85...1.1 Uc at 50 Hz (at < 55 °C)
Drop-out: 0.3...0.6 Uc at 50 Hz (at < 55 °C)
operating time 20...26 ms on closing
8...12 ms on opening
mechanical durability 5000000 cycles
maximum operating rate 1200 cyc/h 60 °C
inrush power in VA 160 VA 50 Hz cos phi 0.75 (at 20 °C)
140 VA 60 Hz cos phi 0.75 (at 20 °C)
hold-in power consumption in VA 15 VA 50 Hz cos phi 0.3 (at 20 °C)
13 VA 60 Hz cos phi 0.3 (at 20 °C)
heat dissipation 6…10 W for control circuit
minimum switching current 5 mA for control circuit
minimum switching voltage 17 V for control circuit
non-overlap time 1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
insulation resistance > 10 MOhm for control circuit
electrical durability 350000 cycles AC-1
900000 cycles AC-3
mounting support DIN rail
Plate
connections - terminals Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: solid without cable end
Recommended tightening torque Control circuit: 1.2 N.m
Power circuit: 5 N.m
Max tightening torque Control circuit: 1.4 N.m
Power circuit: 5.8 N.m

Environment

standards IEC 60947-4-1
IEC 60947-1
IEC 60947-5-1
product certifications EAC
IP degree of protection IP2x conforming to IEC 60529
protective treatment TH (pollution degree 3) conforming to IEC 60068
pollution degree 3
ambient air temperature for operation -5…55 °C
ambient air temperature for storage -60…80 °C
permissible ambient air temperature around the device -20…70 °C at Uc
operating altitude 3000 m without derating
fire resistance 850 °C conforming to IEC 60695-2-1
mechanical robustness Vibrations contactor open: 1.5 Gn, 5...300 Hz
Vibrations contactor closed: 3 Gn, 5...300 Hz
Shocks contactor open: 6 Gn for 11 ms
Shocks contactor closed: 7 Gn for 11 ms

Dimensions and connection

Sizes of LC1E65M5        LC1-E6511 circuit

Auxiliaries and accessories for LC1E65M5

background
LAEN11
 
 
background
LAEM1
 
 
background
LAEN22
 
 
background
LAERCU
 
 

Similar or replacement products LC1E65M5

background
LC1-D6511-220VAC
 
 
background
CJX2-D6511 220V
 
 
background
PMU6511M
 
 
Questions