Motor circuit breaker TeSys GV3P18

  • Model: 003.002.179
Motor circuit breaker TeSys GV3P18
Manufacturer: Schneider Electric
Barcode: 3389119405362

The TeSys GV3P18 circuit breaker is designed for the protection and control of 7.5kW electric motors (at 400...415Vac 50/60Hz).

The switch combines the following functions:
  • short circuit and overload protection
  • motor on / off control
  • contact position indication
Main characteristics:
  • combination release
  • thermal protection setting range 12…18A

Main

rangeTeSys
product nameTeSys GV3
product or component typeCircuit breaker
device short nameGV3P
device applicationMotor
trip unit technologyThermal-magnetic

Complementary

poles description3P
network typeAC
utilisation categoryAC-3 conforming to IEC 60947-4-1
Category A conforming to IEC 60947-2
network frequency50/60 Hz conforming to IEC 60947-4-1
fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
operating positionAny position
motor power kW7.5 kW at 400/415 V AC 50/60 Hz
9 kW at 500 V AC 50/60 Hz
15 kW at 690 V AC 50/60 Hz
breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
control typeRotary knob
[In] rated current18 A
thermal protection adjustment range12…18 A
magnetic tripping current252 A
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal current18 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage6 kV IEC 60947-2
power dissipation per pole8 W
mechanical durability50000 cycles
electrical durability50000 cycles for AC-3 at 440 V In
maximum operating rate25 cyc/h
rated dutyContinuous conforming to IEC 60947-4-1
tightening torque5 N.m on EverLink BTR screw connectors for cable 25 mm²
8 N.m on EverLink BTR screw connectors for cable 35 mm²
suitability for isolationYes conforming to IEC 60947-1
phase failure sensitivityYes conforming to IEC 60947-4-1
height132 mm
width55 mm
depth136 mm
net weight0.96 kg

Environment

standardsEN/IEC 60947-2
EN/IEC 60947-4-1
CSA C22.2 No 60947-4-1
UL 60947-4-1
product certificationsIECEE CB Scheme
UL
CSA
CCC
EAC
ATEX
BV
LROS (Lloyds register of shipping)
DNV-GL
ABS
protective treatmentTH
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK09
ambient air temperature for operation-20…60 °C
ambient air temperature for storage-40…80 °C
fire resistance960 °C conforming to IEC 60695-2-1
operating altitude3000 m

Dimension

Dimensions of the circuit breaker GV3P series
Electrical clearance X1=40mm for Ue≤ 500V
and X1=50mm for Ue≤ 690V

Scheme

Electrical scheme of the circuit breaker GV3P series

Range of TeSys GV3P series circuit breakers

Model Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 Setting range of thermal trips Magnetic tripping current Id ± 20 %
400/415V 500V 690V
P Icu Ics P Icu Ics P Icu Ics
kW kA % kA kA % kW kA % A A
GV3P13 5.5 100 100 7.5 12 50 11 6 50 9...13 182
GV3P18 7.5 100 100 9 12 50 15 6 50 12...18 252
GV3P25 11 100 100 15 12 50 18.5 6 50 17...25 350
GV3P32 15 100 100 18.5 12 50 22 6 50 23...32 448
GV3P40 18.5 50 100 22 12 50 37 6 50 30...40 560
GV3P50 22 50 100 30 12 50 45 6 50 37...50 700
GV3P65 30 50 100 45 12 50 55 6 50 48...65 910
GV3P73 37 50 60 45 12 50 55 6 50 62...73 1120
GV3P80 45 50 60 45 12 50 55 6 50 70...80 1120

Auxiliaries and accessories for GV3P18

background
GV3APN01
 
 
background
GV3APN02
 
 
background
GV3APN04
 
 
background
GVAED101
 
 
background
GVAD0101
 
 
background
GVAN20
 
 
background
GVAN11
 
 
background
GVAE11
 
 
background
GVAU385
 
 
background
GVAS225
 
 
background
GVAD1010
 
 
Questions
WhatsAppTelegramViberVKemail