Circuit breaker Easy9 EZ9F34410 4P 10A C 4.5kA 400V AC

  • Model: 003.002.357
Circuit breaker Easy9 EZ9F34410
Manufacturer: Schneider Electric
Barcode: 3606480589393
Easy9 EZ9F34410 circuit breaker is designed to perform the following functions:
  • protection of circuits against short-circuit currents
  • overload current protection
Fault-tripping indication on the front panel by the position of the handle (O-I engraved).
$8.26
 pcs

Main

rangeEasy9
device applicationDistribution
product or component typeMiniature circuit-breaker
device short nameEasy9 MCB
Poles4P
number of protected poles4
[In] rated current10 A
network typeAC
trip unit technologyThermal-magnetic
curve codeC
breaking capacity4500 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1
4500 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1
suitability for isolationYes conforming to IEC 60898-1

Complementary

network frequency50 Hz
[Ue] rated operational voltage400 V AC 50 Hz
magnetic tripping limit5...10 x In
[Ics] rated service breaking capacity4.5 kA 100 % x Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to IEC 60898-1
[Uimp] rated impulse withstand voltage4 kV conforming to IEC 60898-1
contact position indicatorYes
control typeToggle
local signallingWithout
mounting modeClip-on
mounting supportDIN rail
9 mm pitches8
height81 mm
width72 mm
depth66.5 mm
colourGrey (RAL 7035)
mechanical durability10000 cycles
electrical durability4000 cycles
connections - terminalsTunnel type terminal (top or bottom) 1…25 mm² rigid
Tunnel type terminal (top or bottom) 1…16 mm² flexible
tightening torque2 N.m top or bottom

Environment

standardsIEC 60898-1
product certificationsGOST-R
IP degree of protectionIP20 conforming to IEC 60529
pollution degree2
tropicalisation2
relative humidity95 % at -25…60 °C
ambient air temperature for operation-25…60 °C
ambient air temperature for storage-40…85 °C

Dimensions

Circuit breaker dimensions

Model range of Easy9 series circuit breakers

Number of poles Rated current, A Schneider Electric catalogue number
Curve B Curve C
1

Type designation 1P
6 EZ9F14106 EZ9F34106
10 EZ9F14110 EZ9F34110
16 EZ9F14116 EZ9F34116
20 EZ9F14120 EZ9F14120
25 EZ9F14125 EZ9F34125
32 EZ9F14132 EZ9F34132
40 EZ9F14140 EZ9F34140
50 EZ9F14150 EZ9F34150
63 EZ9F14163 EZ9F34163
2

Type designation 2P
6 EZ9F14206 EZ9F34206
10 EZ9F14210 EZ9F34210
16 EZ9F14216 EZ9F34216
20 EZ9F14220 EZ9F34220
25 EZ9F14225 EZ9F34225
32 EZ9F14232 EZ9F34232
40 EZ9F14240 EZ9F34240
50 EZ9F14250 EZ9F34250
63 EZ9F14263 EZ9F34263
3

Type designation 3P
6 EZ9F14306 EZ9F34306
10 EZ9F14310 EZ9F34310
16 EZ9F14316 EZ9F34316
20 EZ9F14320 EZ9F34320
25 EZ9F14325 EZ9F34325
32 EZ9F14332 EZ9F34332
40 EZ9F14340 EZ9F34340
50 EZ9F14350 EZ9F34350
63 EZ9F14363 EZ9F34363
4

Type designation 4P
6 EZ9F14406 EZ9F34406
10 EZ9F14410 EZ9F34410
16 EZ9F14416 EZ9F34416
20 EZ9F14420 EZ9F34420
25 EZ9F14425 EZ9F34425
32 EZ9F14432 EZ9F34432
40 EZ9F14440 EZ9F34440
50 EZ9F14450 EZ9F34450
63 EZ9F14463 EZ9F34463

Dimensions

Circuit breakers dimensions
Questions
WhatsAppTelegramViberVKemail