Circuit breaker TX³ 404044 2P 25A C 6kA

Model: 003.020.131
  • photo 3
  • photo 4
Circuit breaker TX³ 404044
Manufacturer: Legrand
The TX³ 404044 circuit breaker is designed to control loads, disconnect electrical circuits and protect against overload and short circuit.
Price by call

Specification

General characteristics
Number of poles2
Rated current(In)25A
Rated operating voltage230/400VAC 50/60Hz
Insulation voltage500V
Impulse withstand voltage4kV
Magnetic tripping curveC (between 5 and 10 In)
Thermal tripping at ambient temperature30°C
Rated breaking capacity6kA
Energy limiting class3
Complementary characteristics
Degree of protectionIP20
Operating temperature-25°C...+70°C
Storage temperature-40°C...+70°C
Mechanical life20 000 ops (no load)
10 000 ops (under load In × cosφ 0,9)
Mounting positionany
Installation35mm DIN rail
Connection
Cross-section of copper wire1 × 1,5...25 mm2 (rigid)
1 × 1,5...16 mm2 (flexible, without cable end)
1 × 1,5...16 mm2 (flexible, with cable end)
Tightening torque2,5 N·m

Dimensions

Dimensions circuit breaker TX3 2P

Range of Legrand TX3 series circuit breakers

Number of poles 1 2 3 4
Rated current, A Tripping curves
B C B C B C B C
6 4 039 69 4 040 25 4 039 83 4 040 39 4 039 97 4 040 53 4 040 11 4 040 67
10 4 039 70 4 040 26 4 039 84 4 040 40 4 039 98 4 040 54 4 040 12 4 040 68
16 4 039 72 4 040 28 4 039 86 4 040 42 4 040 00 4 040 56 4 040 14 4 040 70
20 4 039 73 4 040 29 4 039 87 4 040 43 4 040 01 4 040 57 4 040 15 4 040 71
25 4 039 74 4 040 30 4 039 88 4 040 44 4 040 02 4 040 58 4 040 16 4 040 72
32 4 039 75 4 040 31 4 039 89 4 040 45 4 040 03 4 040 59 4 040 17 4 040 73
40 4 039 76 4 040 32 4 039 90 4 040 46 4 040 04 4 040 60 4 040 18 4 040 74
50 4 039 77 4 040 33 4 039 91 4 040 47 4 040 05 4 040 61 4 040 19 4 040 75
63 4 039 78 4 040 34 4 039 92 4 040 48 4 040 06 4 040 62 4 040 20 4 040 76
Number of poles 1 2 3 4
Rated current, A Tripping curves
B C B C B C B C
6 4 038 57 4 039 13 4 038 71 4 039 27 4 038 85 4 039 41 4 038 99 4 039 55
10 4 038 58 4 039 14 4 038 72 4 039 28 4 038 86 4 039 42 4 039 00 4 039 56
13 4 039 15 4 039 29 4 039 43 4 039 57
16 4 038 60 4 039 16 4 038 74 4 039 30 4 038 88 4 039 44 4 039 02 4 039 58
20 4 038 61 4 039 17 4 038 75 4 039 31 4 038 89 4 039 45 4 039 03 4 039 59
25 4 038 62 4 039 18 4 038 76 4 039 32 4 038 90 4 039 46 4 039 04 4 039 60
32 4 038 63 4 039 19 4 038 77 4 039 33 4 038 91 4 039 47 4 039 05 4 039 61
40 4 038 64 4 039 20 4 038 78 4 039 34 4 038 92 4 039 48 4 039 06 4 039 62
50 4 038 65 4 039 21 4 038 79 4 039 35 4 038 93 4 039 49 4 039 07 4 039 63
63 4 038 66 4 039 22 4 038 80 4 039 36 4 038 94 4 039 50 4 039 08 4 039 64

Dimensions and tripping curves

TX3 series breakers dimensions
TX3 series tripping curves

Auxiliaries and accessories for 404044

Similar or replacement products 404044

Questions
WhatsAppTelegramViberVKemail