Circuit breaker C120N A9N18360 2P 63A C

  • Model: 003.001.021
Circuit breaker C120N A9N18360
Manufacturer: Schneider Electric
Barcode: 3606480379345
The C120N A9N18360 circuit breaker meets the requirements of the standards EN 60947-2, EN 60898-1 and combines the following functions:
  • protection of circuits against short-circuit currents
  • overload current protection
  • possibility of partitioning in industrial electrical installations in accordance with IEC / EN 60947-2
  • fault signaling and emergency shutdown by means of optional accessories

Main

range of productC120
rangeActi 9
product nameC120
product or component typeMiniature circuit-breaker
device short nameC120N
device applicationDistribution
poles description2P
number of protected poles2
neutral positionLeft
[In] rated current63 A at 30 °C
network typeAC
trip unit technologyThermal-magnetic
curve codeC
breaking capacity10000 A Icn at 230...400 V AC 50/60 Hz conforming to EN/IEC 60898-1
6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at ≤ 250 V DC conforming to EN/IEC 60947-2
20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
suitability for isolationYes conforming to IEC 60947-2

Complementary

network frequency50/60 Hz
[Ue] rated operational voltage380...415 V AC 50/60 Hz
220...240 V AC 50/60 Hz
440 V AC 50/60 Hz
≤ 250 V DC
230...400 V AC 50/60 Hz
magnetic tripping limit5...10 x In
[Ics] rated service breaking capacity7500 A 75 % conforming to EN/IEC 60898-1 - 230...400 V AC 50/60 Hz
4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz
15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz
10 kA 100 % conforming to EN/IEC 60947-2 - ≤ 250 V DC
limitation class3 conforming to EN/IEC 60947-2
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-2
contact position indicatorYes
control typeToggle
local signallingON/OFF indication
mounting modeClip-on
mounting support35 mm symmetrical DIN rail
comb busbar and distribution block compatibilityYES
9 mm pitches6
height81 mm
width54 mm
depth73 mm
net weight0.41 kg
colourWhite
mechanical durability20000 cycles
electrical durability10000 cycles conforming to IEC 60947-2
connections - terminalsTunnel type terminals1…50 mm² rigid
Tunnel type terminals1.5…35 mm² flexible
wire stripping length15 mm
tightening torque3.5 N.m
earth-leakage protectionSeparate block

Environment

standardsEN/IEC 60898-1
EN/IEC 60947-2
product certificationsEAC
IP degree of protectionIP20 conforming to IEC 60529
pollution degree3 conforming to IEC 60947-2
overvoltage categoryIV
tropicalisation2 conforming to IEC 60068-1
relative humidity95 % at 55 °C
operating altitude2000 m
ambient air temperature for operation-25…70 °C
ambient air temperature for storage-40…85 °C

Schneider Electric nomenclature of C120N circuit breakers

Poles Number of modules W=9mm Rated current, A Part No. Schneider Electric / Price
Curve B Curve C Curve D
1
обозначение однополюсного выключателя
3 63 A9N18340
A9N18356
A9N18378
80 A9N18341
A9N18357
A9N18379
100 A9N18342
A9N18358
A9N18380
125 A9N18343
A9N18359
A9N18381
2
обозначение двухполюсного выключателя
6 63 A9N18344
A9N18360
A9N18382
80 A9N18345
A9N18361
A9N18383
100 A9N18346
A9N18362
$203.55
A9N18384
125 A9N18347
A9N18363
A9N18385
3
обозначение трехполюсного выключателя
9 63 A9N18348
A9N18364
$185.78
A9N18386
$463.54
80 A9N18349
A9N18365
A9N18387
100 A9N18350
A9N18367
A9N18388
125 A9N18351
A9N18369
A9N18389
4
обозначение четырёхполюсного выключателя
12 63 A9N18352
A9N18371
A9N18390
80 A9N18353
A9N18372
A9N18391
100 A9N18354
A9N18374
A9N18392
125 A9N18355
A9N18376
A9N18393

Dimensions circuit breaker C120N

Dimensions circuit breaker C120N

Trip curves

Curve В Curve C Curve D
Questions
WhatsAppTelegramViberVKemail